What is the minimum radius that the 6mm Siniat Contour board can bend for the installation of a curved partition?
The minimum radius is 900mm and this is achieved by installing the board horizontally using a GTEC deep flange flex track, GTEC C-studs at 200mm centres and fixing the boards to a continuous band of GTEC Flat strap backing the horizontal joints.
Didn't find what you are looking for? Contact our Technical Support